UPS sales, installation and service from 1KVA to 2000KVA in Faisalabad — load survey, battery bank sizing, proper commissioning and maintenance that actually keeps the unit alive.
Most UPS problems we are called out to in Faisalabad were caused at installation, not by the equipment. A UPS is an electronic device connected to a battery bank, and both halves have to be right: the battery bank must match the unit's DC bus voltage and have enough cells in series, and the DC cable gauge must be sized for both the charge current and the short-circuit current the bank can deliver.
A 5KVA UPS on a bank with two undersized interlinks will work perfectly in the shop and then fail at 2am when the cells are cold and the fault current is highest. Cable gauge is not a place to save money, and neither is earthing or the changeover arrangement.
We carry common spares for the brands we sell, which means most faults are resolved without a return-to-workshop delay. The most common faults in Faisalabad's climate are electrolytic capacitors drying out, cooling fan bearings failing, control card and display faults, IGBT and SCR power module failures, and battery banks that have simply reached the end of their life.
We work on systems from 1KVA up to 2000KVA, single-phase and three-phase. For larger units we bring a load bank so we can test the inverter stage under a realistic load rather than proving it with a light bulb.
The difference between a UPS that lasts eight years and one that is replaced at four is usually maintenance. Heat is the enemy: a unit running in a hot, poorly ventilated room ages several times faster than the same unit in an air-conditioned room, and Faisalabad summers are not gentle on an unventilated cabinet.
A maintenance visit covers a load test, capacitor and fan inspection, battery bank capacity testing, terminal and connection torque checks, cleaning of the air filters and vents, and a written report. For clinics, factories and offices that cannot afford an outage, an annual contract is straightforwardly cheaper than an emergency replacement.
Jump straight to the range you were looking for, or ask our trade desk for a rate.
Yes. We repair UPS in Faisalabad from 1KVA to 2000KVA, single-phase and three-phase, covering capacitors, fans, control cards, IGBT and SCR power modules, transformers, fuses and battery banks.
Yes. Installation includes a load survey, a battery bank matched to the DC bus voltage, correctly gauged copper cable, earthing and phase-balance verification, and a changeover test on your real load before handover.
Installation cost depends on the kVA rating, the battery bank size and the cable run. Once we have surveyed the site we quote the whole job including cable and interlinks, so there are no extras added afterwards.
At least annually, and twice a year in a hot room. Heat drives capacitor failure and fan wear, and a routine visit catches both before they take the inverter stage with them.
Usually one of three things: the battery bank has aged and cannot supply the current, the DC interlinks are undersized, or the load has grown beyond what the unit was sized for. Bring the model and kVA rating and we will test rather than guess.
Yes. We offer annual and bi-annual maintenance contracts covering load testing, capacitor and fan inspection, battery capacity testing, connection checks and a written condition report, with priority response for contracted sites.
Walk in during trading hours, or send us the model and quantity on WhatsApp and we will confirm stock, rate and dispatch time the same day.