Emerson Liebert NXa 30kVA 3-Phase UPS
High-performance 30kVA / 24kW true online double-conversion 3-phase UPS with internal battery and digital signal processing (DSP) control.
Loading catalog & live prices...

Ultra-high capacity 3-phase online double-conversion industrial UPS (800 kVA / 640 kW) engineered for tier-4 data centers, massive infrastructure complexes, and heavy industrial automation grids.
Contact us directly on WhatsApp to get the latest live rates & discounts.
The Schneider Electric / APC MGE Galaxy 6000 800 kVA is the ultimate power capacity milestone within the rugged Galaxy 6000 series lineup. Delivering a massive 640 kW of clean, continuous active power at a 0.8 power factor, it operates on a strict online double-conversion VFI (Voltage and Frequency Independent) topology. This system provides total physical separation from utility grid failures, high-voltage surges, and voltage distortions. Featuring modular scalability that supports parallel clustering of up to 6 units (scaling up to 4.8 MVA total plant capacity), integrated Total Harmonic Management (THDI < 4%), and highly reliable IGBT inverter blocks, it ensures unmatched operational lifespan and maximum uptime under full enterprise loads.
Massive Parallel Scale: Scale up to 4.8 MVA capacity using parallel-redundant configurations for complete TIER IV compliance.
Advanced THM Performance: Filters downstream harmonics dynamically (<4% THDI), allowing sleek matching with large standby gensets.
Rapid Charger Integration: Intelligent battery charging structures ensure full heavy-duty string recharges in less than 11 hours.
Dual Input Main Provision: Isolates utility grids to feed the internal power rectifier and the static automatic bypass systems independently.

High-performance 30kVA / 24kW true online double-conversion 3-phase UPS with internal battery and digital signal processing (DSP) control.
| Capacity (kVA / kW) | 800 kVA / 640 kW (0.8 Power Factor) |
|---|---|
| UPS Topology | On-Line Double Conversion (VFI-SS-111) |
| Input Nominal Voltage | 380V / 400V / 415V AC (3-Phase + Neutral + Ground) |
| Input Voltage Range | 320V – 466V AC (Handles severely disturbed distribution systems) |
| Input Frequency | 50 Hz / 60 Hz (±10% auto-sensing) |
| Input Power Factor / THDI | > 0.95 / THDI < 4% (With integrated THM phase-shifting filters) |
| Output Voltage | 380V / 400V / 415V AC (Three-phase) |
| Output Voltage Regulation | ±1% static regulation |
| Output Nominal Current | ~1,154 Amps |
| Overload Capacity | 125% for 10 minutes, 165% for 1 minute |
| System Efficiency | Up to 95% efficiency even at partial 50% load factors |
High-performance 40kVA / 32kW true online double-conversion 3-phase UPS with internal battery and digital signal processing (DSP) control.

High-performance 60kVA / 48kW true online double-conversion 3-phase UPS (without internal battery) with digital signal processing (DSP) control.