Emerson Liebert NXa 30kVA 3-Phase UPS
High-performance 30kVA / 24kW true online double-conversion 3-phase UPS with internal battery and digital signal processing (DSP) control.
Loading catalog & live prices...

Industrial-grade 3-phase online double-conversion UPS (250 kVA / 200 kW) designed for medium data centers, telecom central nodes, and critical medical imaging facilities.
Contact us directly on WhatsApp to get the latest live rates & discounts.
The Schneider Electric / APC MGE Galaxy 6000 250 kVA is a heavy-duty, three-phase uninterruptible power supply engineered to provide complete electrical isolation and robust power conditioning for highly sensitive loads. Delivering 200 kW of clean continuous power at a 0.8 power factor, this unit operates on a true online double-conversion VFI architecture. Key design metrics include parallel system integration (up to 6 units), an integrated input harmonic filter keeping THDI below 4%, and dual mains input routing. This makes it perfectly compatible with high-capacity backup generators while maintaining peak operation for server infrastructures and facility loads.
Total Harmonic Management (THM): Built-in input current optimization filters distortion (<4% THDI) to maximize generator efficiency.
DigiBat Battery Diagnostics: Smart battery care platform for precise dynamic runtime analytics and longevity management.
Front-Access Design: Reduces overall floor footprint requirements by allowing flush back-to-wall installation.
Dual Mains Architecture: Feeds the inverter block and the automatic static bypass lines independently.

High-performance 30kVA / 24kW true online double-conversion 3-phase UPS with internal battery and digital signal processing (DSP) control.
| Capacity (kVA / kW) | 250 kVA / 200 kW (0.8 Power Factor) |
|---|---|
| UPS Topology | On-Line Double Conversion (VFI-SS-111) |
| Input Nominal Voltage | 380V / 400V / 415V AC (3-Phase + Neutral + Ground) |
| Input Voltage Range | 323V – 470V AC |
| Input Frequency | 50 Hz / 60 Hz (±10% auto-sensing) |
| Input Power Factor / THDI | > 0.95 / THDI < 4% (with active harmonic filter) |
| Output Voltage | 380V / 400V / 415V AC (Three-phase) |
| Output Voltage Regulation | ±1% static regulation |
| Output Nominal Current | ~360 Amps |
| Overload Capacity | 125% for 10 minutes, 165% for 1 minute |
| System Efficiency | Up to 95% at standard nominal load profiles |
| Paralleling capability | Connect up to 6 units in parallel for capacity or redundancy |
| Battery Options | Supports VRLA (Sealed Lead Acid), Flooded Wet Cells, and NiCd battery banks |
High-performance 40kVA / 32kW true online double-conversion 3-phase UPS with internal battery and digital signal processing (DSP) control.

High-performance 60kVA / 48kW true online double-conversion 3-phase UPS (without internal battery) with digital signal processing (DSP) control.